PH Meters Manufacturers India

Digital PH Meter KI 262a

DIGITAL PH METER [MODEL NO. KI- 262 (A)]

pH Range : 0 to 14
Resolution : 0.01
Accuracy and Repeatability : ± 0.01
mV Range : 0 to ± 2000
Accuracy : ± 0.1%
Repeatability : ± 1 digit
Asym. Potential Correction : ± 100 mV with 1 turn Potentiometer
Temp. Compensation : 0 to 100°C manual
Readout : 3½ Digit 7 segment LED display
Accessories : Stand with clamp, temperature probe combination electrode
Additional Feature : Manual slope correction

PH Meter Microprocessor KI 262c

MICROPROCESSOR BASED PH METER (GRAPHICAL DISPLAY)[MODEL NO. KI- 262 (C)]

Range : 0.00-14.00Ph
Resolution : 0.01 pH
Accuracy : ±0.01 pH relative
Slope adjustment : 80% to 120% (default 100%)
Temp. compensation : 0 to 100ºC (auto/manual)
Auto buffer recognition : 4.00, 7.00 & 9.20
Calibration : 2 pt and 3 pt Auto/Manual using software mv
Range : -1999 to 1999 mv
Resolution : 1 mV
Accuracy : ±0.1% + 1 digit
Calibration : 2 point manual using software

TEMPRATURE

Range : -20 to 200ºC
Resolution : 0.1ºC
Accuracy : + 0.1% of range + 1 digit
Calibration : 2 pt manual using software
Sensor : PT 100 Probe

GENERAL

Display : 128 x 64 graphical LCD with backlight
Data Entry : By 5 soft touch keys
Storage : 1000 samples
Real Time Clock : 24 hour mode with date
Print format : All data and date wise (user selectable)
Digital Output : USB
Power Supply : 230V AC +10% 50 Hz

KEY FEATURES
  • Simultaneous display of temperature, pH, mV, pH calibration type, and sample number.
  • Automatic shift to manual mode for temperature compensation in case the temperature is more than 100ºC for pH measurements.
  • Icon based graphical menu for easy navigation.
  • USB interface for transferring data to PC.
  • Large font size of pH for easy reading of pH data.
  • Display of stored data on GLCD with date and time.
  • Error codes while pH calibration- “S.BUFF” in case the same buffer is used again or “U.BUFF” in case the buffer value is other than 4.00, 7.00 and 9.20.
  • Error codes in case of ORP calibration- “ORP ERROR” if same value is being again for calibration.
  • Error codes in case of temperature calibration: “T.ERROR” if same value is used again for calibration.
Conductivity Meter Microprocessor KI 263b

MICROPROCESSOR BASED CONDUCTIVITY METER [MODEL NO. KI- 263 (B)]

SALIENT FEATURES
  • 128×64 dots Graphical LCD Display
  • EC, TDS, Salinity & Temperature Measurements.
  • Auto temperature Compensation.
  • Auto ranging facility.
  • Programmable Ref. Tem & Temp. Coeff in EC Mode.
  • 1000 samples storage facility.
  • Printer attachment facility.
TECHNICAL SPECIFICATION
PARAMETERECTDSSALINITYTEMP.
Range Sel.AutomaticAutomaticAutomatic-----
Range0-20, 0-200µs 0-2, 0-20, 0-200ms0-2, 0-20, 0-200ppm 0-20, 0-200ppt0-20, 0-200 ppm 0-2, 0-20, 0-50 ppt0-100°C
Accuracy±0.5%FS±1Digit±0.5%FS±1Digit±1%FS±1Digit±0.1°C
Resolution0.01 µs0.01 ppm 0.01 ppm0.1°C----
Cell Const.Adjustable (0.05-9.99)Adjustable (0.05-9.99)Adjustable (0.05-9.99)----
Temp. CompAuto/Manual 0-50°CAuto/Manual 0-50°CAuto/Manual 0-50°C----
Temp. Coeff.Adjustable (0.1-4.0%)Adjustable (0.1-4.0%)Adjustable (0.1-4.0%)----
Readout128x64 dots Graphical LCD display
Key Board5 Soft touch membrane type keys.
PrinterUSB Interface
StorageUp to 1000 Samples
Power230V ± 10% AC
Accessories Cond./TDS/Salinity Cell, Temperature Probe, Electrode Stand, Mains Lead, Dust Cover, Instruction Manual
DIGITAL CONDUCTIVITY METER

DIGITAL CONDUCTIVITY METER [MODEL NO. KI- 263 (C)]

TECHNICAL SPECIFICATION

Display : 3½ digit LED
Measurement : Conductivity
Conductivity Ranges : Five Ranges
Range Selection : automatic in 5 ranges
Temp. range Accuracy : -5 to 110ºC
Conductivity : ±0.5% FS ± 1 Digit
Temperature : ±0.1% ± 1 Digit
Temp. Compensation : Auto: 0 to 50ºC
Cell constant : Adjustable on digital display
Measuring cell : Platinum DIP type
Cell const. measurement: Auto
Power : 230V ± 10% AC
Dimensions : 270 x 202 x 80 mm (LxBxH)
Weight : 0.8 kg approx.
Accessories : conductivity cell, operation manual, dust cover, cell stand, temperature Probe

Spectrophotometer KI 268b

MICROPROCESSOR BASED DIGITAL UV-VIS SPECTROPHOTOMETER [MODEL NO. KI- 268 (B)]

UV-Visible spectrophotometer, an analytical instrument commonly used in physic-chemical laboratories to make quantitative and qualitative analysis of specimen materials in the ultraviolet, visible spectral range finds much scope for its service in such fields as medicine, clinical examination, biochemistry, petro-chemical industry, Bio technology Environmental protection and quality control. The technique has enjoyed a molecular biology and the need to quantify DNA and proteins. Here the simplicity of use, the non-destructive nature of the sampling and the cost effectiveness of the measurement has proved very beneficial in the modern laboratory.

SALIENT FEATURES
  • Large LCD Screen (128×64 Dots).
  • Data can be restored after a sudden power cut.
  • Automatic wavelength setting.
  • Tungsten lamp & deuterium lamp can be turned on/off individually.
  • Automatic wavelength calibration and dark current getting.
  • Covers 200 to 1000 nm.
  • 4 position Cuvette Holder.
  • USB & Parallel port for printing.
TECHNICAL SPECIFICATION
KEY FEATURES

Optical System : Single beam, Grating 1200 lines/mm
Wavelength Range : 200-1000nm
Spectral bandwidth : 1nm
Wavelength accuracy : ±0.5nm
Wavelength repeatability : ±0.1nm
Wavelength Setting : Automatic
Photometric Accuracy : ±0.1%T
Photometric repeatability : ±0.3%T
Photometric Range : -0.3 to 3.0A, 0 to 200% T
Stray Light : ≤0.3%T
Stability : ±0.002A/h @ 500nm
Display : 128 x 64 Dots LCD
Detector : Silicon Photodiode
Standard Cell Holder : 4- Position 10mm cell changer
Light Source : Tungsten & Deuterium lamp
Output : USB port & Parallel port
Power : AC 220V/50Hz Single Phase
Weight : 12 kg

Spectrophotometer Double BeamTS KI 268d

DOUBLE BEAM MICROPROCESSOR UV-VIS SPECTROPHOTOMETER [MODEL NO. KI- 268 (D)]

The perfectly designed double beam UV/VIS Spectrophotometer successfully realizes high accuracy and reliability measurement to meet various application requirements. It can be used extensively for qualitative and quantitative analysis in such fields as biochemical research and industry, pharmaceutical analysis and production, education, environmental protection, food industry, clinical examination, sanitation and antiepidemic etc.

SALIENT FEATURES
  • Wide wavelength range, satisfying requirements of various fields.
  • Fully automated design, realizing the simplest measurement & satisfying the requirements of pharmacopoeia.
  • Maximum of 9 Wavelengths & 7 samples can be measured at one time.
  • Automatic change-over between W lamp & D2 lamp.
  • Optimized optics and large scale integrated circuits design, light source and receiver from world famous measurement all add up to high performance and reliability.
  • Rich measurement methods: wavelength scan, time scan, multi-wavelength determination, multi-order derivative determination, double-wavelength method and triple-wavelength method etc. meet different measurement requirement.
  • Automatic 10mm 8 cell holder.
  • Data output can be obtained via a printer port and a RS 232 interface.
  • Parameters and data can be saved for user’s convenience.
  • PC controlled measurement can b achieved for more accurate and flexible requirement.
TECHNICAL SPECIFICATIONS

Wavelength Ramge : 190-1100 nm
Spectral Bandwidth : 1nm
Working Mode : T, A, C, E
Optical System : Double beam
Scanning Speed : Fast/Medium/Slow
Photometric Range : -0.3-3.5A, 0 to 220 % T
Wavelength Accuracy : ±0.3 nm
Wavelength Reproducibility : < 0.10nm
Photometric Accuracy : ±0.3%T (0~100%T), ±0.002A (0~0.1 A)
Photometric Reproducibility : < 0.15%T
Stray Light : < 0.1%T (Nal. 220nm, NaNO2 340 nm)
Baseline Flatness : ±0.002A
Stability : < 0.001A/h (at 500 nm, after warming up)
Noise : ±0.001A (at 500 nm, after warming up)
Detector : Dual Silicon Photodiode
Display : 6 inches high light blue LCD
Power : AC: 220V ± 10%, 50 Hz
Dimensions Weight : 630 x 470 x 210 mm

ACCESSORIES

Glass Cells : 16 Nos.
Quartz Cells : 04 Nos.
Fuse : 03 Nos.
Instrument Cover : 01 No.
Software CD : 01 No.
RS 232 Cable : 01 No.
Operation Manual : 01 No.

Digital Flame Photometer With Compresor KI 269a

DIGITAL FLAME PHOTOMETER, Model No. KI-269(a)

SALIENT FEATURES
  • Dual Channel Display
  • Narrow Band interference Filters
  • Simple & Easy to operate
  • Na & K at Single Aspiration
TECHNICAL SPECIFICATION
No. of FilterNa & KCa & Li optional
RangeNa: 0-100 ppm
K: 0-100 ppm
Ca: 20-100 ppm
Li: 10-100 ppm
SenstivityNa: 1 ppm
K: 1 ppm
Ca: 15 ppm
Li: 15 ppm
Display2½ digit bright red LED display
Accuracy±2% up to 40 ppm
±5% above 40 ppm
Repeatability±2 Count
DetectorSilicon Photodiode
FiltersNarrow band interface glass
NebulizerBlack Bakelite, axial flow type
Flame SystemLPG and dry oil free air
Warm up time10 minutes
Power230V±10% AC, 50Hz
Size(LxBxH)355x250x210 mm
Weight6.5 kg (Approx.)
Flame Photometer KI 269b

MICROPROCESSOR BASED FLAME PHOTOMETER [MODEL NO. KI- 269 (B)]

FEATURES & FUNTIONS
  • Four element measurement in a single aspiration (Na, K, Li and Ca)
  • Calibration curve fit routines first order and second order.
  • Data displayed in concentration units i.e ppm and meq
  • Automatic filter selection, auto calibration feature.
  • Printer attachment, PC connecting compatibility.
  • Sample data storage, more than 500 results.
  • Alphanumerical key board for easy data entry.
  • Graphical LCD display thus easy to read.
  • Curve calibration using up to 5 standards.
  • Multiple calibration curve saving facility.
  • Stainless steel burner.
TECHNICAL SPECIFICATION
Mode General Analytical SerumUrine
Range Na: 0.1-100 ppm Upto 250 meq/L, 1:100 dilution K: 0.1-100 ppm Upto 250 meq/L, 1:100 dilution Ca: 10-100 ppm Upto 250 meq/L, 1:100 dilution Li: 0.5 -100 ppm Upto 250 meq/L, 1:100 dilutionNa: 0-200 1:100 dilution K: 0-10 1:100 dilution Ca-Li: 0-2 1:5 dilutionNa: 0-250 1:100 dilution K: 0-100 1:100 dilution Ca-Li: 0150 1:2 dilution
SenstivityNa: 0.5 ppm, K: 0.5 ppm, Li: 0.5 ppm, Ca: 10 ppm
FiltersFilters for sodium and potassium included: Lithium and calcium extra
Resolution0.1 ppm/meq
RangeSelection Automatic
Reproducibility2% for 25 samples
Curve fit accuracy±2% FS
Display GraphicalLCD Display
Flame SystemLPG and dry oil free air
DetectorSilicon Photodiode
CalibrationUpto 5-point calibration with curve fitting software
Gas ControlFully adjustable
Gas CutoffAutomatic gas cut off on power failure
Ignition SystemAuto ignition
AtomizerRS-232 PC Software available (additional cost)
Power230V±10% AC, 50/60 Hz
Dimensions365x245x220 mm (LxBxH) (Approx)
WeightMain unit: 7.5 kg (approx)
COMPRESSOR UNIT---
Air SupplyOil free compressor unit with pressure regulator & gauge, Built in air filter
Combustion LPGControlled by precision regulator
Power230V ± 10% AC, 50/60 Hz
Dimension290 x 255 x 210 mm (LxBxH) (approx.)
Weight8 kg (approx.)
ELECTRONIC COLONY COUNTER

ELECTRONIC COLONY COUNTER [MODEL NO. KI- 273 (A)]

Digital Colony Counter is designed for quick and accurate counting of bacterial and mould colonies in petri dishes. Feature packed & easy to use, this is an indispensable bench top tool for the busy microbiologist. It is designed for rapid and accurate counting of bacterial and mould colonies. Simply place the petri dish on the illuminated pad and touch the dish with the pen provided to mark each colony in turn. This causes a count to be registered on the digital display and audible tone confirms each count made. Marking the dish with the pen avoids missing colonies or double counting. The digital count on the display can be reset manually any time by pressing the RESET key provided. Optimum viewing of colonies is aided by peripheral glare-free illumination. An integral magnifying glass provides for easier counting of small colonies.

TECHNICAL SPECIFICATIONS

Display : 4 Digit, 9999 Max. Count ; 3 Digit, 999 Max. Count
Dish Size : 110 mm
Magnification : x 1.7
Memory : 50 test
Counting Plate : illuminated wolfhugel
Dimension : L210 x B 270 x H 125 mm (Approx)
Weight : 3 kgs. (Approx)
Packaging : 23cm x 28cm x 20cm Corrugated Carton
Power : 230V-10% AC, 50Hz, 40W
Accessories : Marking Pen- 1 No. ; Magnifier Lens- 1 No.

SALIENT FEATURES
  • Count Correction facility
  • 110 mm Dia magnifying glass
  • Audible confirmation of each count.
  • Uniform glare free illumination
  • Digital readout from 0-9999
  • Auto maker pen.
  • Wloffhuegel glass grid with focusing facility.
DIGITAL TURBIDITY METER

DIGITAL TURBIDITY METER [MODEL NO. KI- 274 (C)]

SALIENT FEATURES
  • Digital LCD Display
  • Reliable & accurate results
  • Sewage & drinking water testing
  • Measurement up to 1000 NTU.
TECHNICAL SPECIFICATIONS

Model : 0 to 200 NTU, 200 to 1000 NTU, 2 Ranges
Resolution : 0.1 & 1
Accuracy : ±3% FS
Repeatability : 2% Full Scale
Readability : 0.1 & 1.0 NTU 2 Ranges
Sample System : 30 mm clear glass tube
Light Source : 6.8V, Tungsten Halogen Lamp
Detector : Photodiode
Display : LCD Digital Display
Memory Storage : 2 ranges of standard solution & last stored value
Power : 220V ± 10% AC 50 Hz
Size ( L x B x H) : 305 x 305 x 165 mm
Weight : 2 kg (approx)
Accessories : Test tube set, operation manual & dustcover

DIGITAL TURBIDITY METER 1

DIGITAL TURBIDITY METER [MODEL NO. KI- 274 (B)]

SALIENT FEATURES
  • 3½ digit LCD Display
  • Reliable & accurate results
  • Sewage & drinking water testing>
  • Measurement up to 1000 NTU.
TECHNICAL SPECIFICATIONS

Model : 0 to 200 NTU; 200 to 1000 NTU; 2 Ranges
Resolution : 0.1 & 1
Accuracy : ±3% FS
Repeatability : 2% Full Scale
Readability : 0.1 & 1.0 NTU 2 Ranges
Sample System : 30 mm clear glass tube
Light Source : 6.8V, Tungsten Halogen Lamp
Detector : Photodiode
Display : LCD Digital Display
Memory Storage : 2 ranges of standard solution & last stored value
Power : 220V ± 10% AC 50 Hz
Size ( L x B x H) : 305 x 305 x 165 mm
Weight : 2 kg (approx)
Accessories : Test tube set, operation manual & dustcover

DIGITAL D.O METER

DIGITAL D.O METER [MODEL NO. KI- 275 (A)]

Oxygen dissolved in water, often referred to as DO is a very important parameter of water quality and is an index of physical and biological processes going on in water. There are two main source of dissolved oxygen in water (i) Diffusion of oxygen from air to water is physical phenomenon and depends upon solubility of oxygen which, in turn, is influenced by factors like temperature, water movements and salinity etc. photosynthetic activity is a biological phenomenon carried out by autotrophs (mainly phytoplankton) in water and depends upon autotroph population, light conditions, and available gases etc.

TECHNICAL SPECIFICATIONS

Range : D.O.: 0 to 20.0 ppm
Resolution : D.O.: 0.1 ppm
Accuracy : D.O.: 0.1 ppm ± 1 count
Temp. Compensation : 0ºC to 50ºC Manual
Compensation : D.O.: ±3%
D.O. Sensor : Amperometric Gold/Silver membrane type.

GENERAL

Display : 3½ digit LED display
Power : 230V AC ± 10%, 50 Hz
Weight : 2 kg (approx)

STANDARD ACCESSORIES

D.O. Electrode/Probe : 01 No.
Instruction Manual : 01 No.
D.O. Membranes : 10 Nos.

SALIENT FEATURES

High Stable and Accurate.
Digital Display
Gold/Silver sensor (D.O. Probe)
User Friendly.

MICROPROCESSOR BASED D.O METER

MICROPROCESSOR BASED D.O METER [MODEL NO. KI- 275 (C)]

Function DO & temperature simultaneously
Display16 character x 2 lines alphanumeric BL LCD
Power supply230 V ± 10% 50 Hz AC
DO---
Range0 to 20 ppm
Resolution0.1 ppm
Accuracy± 2% ± 1 digit
Pressure adjustment0 to 999 mm of Hg Manual By default 760
Temp. compensation0 to 50 °C Auto with temp probe/Manual with
Salinity Correction0 to 20 gm/l (Manual) By Default (00)
CalibrationAuto as well as manual 2 point
Temperature---
Range-20.0 °C to 200°C
Resolution0.1 °C
Accuracy± 0.1% of range ±1 digit
Calibrationtwo point manual
SensorsPt100 probe
Data entryBy soft touch keys with audible sound
Storage1000 samples
Real time display24 Hour mode with Date
InterfaceRS-232,Centronics & computer
Data entryBy soft touch keys with audible sound
Print formatAll Data Date Wise
Digital outputSerial RS-232 Parallel Centronics
Accessories DO probe Dust cover KCL, Sodium Sulphite Salt Instruction Manual Temp Probe DO Membrane(10)
Water Analysis Kit Microprocessor KI 266a
Water Analysis Kit KI 266b

Water Analysis Kit

ModelModel No. KI-266 AModel No. KI-266 B
ProductMicroprocessor water & soil analysis kit Water & Soil Analysis Kit
Display16 x 2 characters LCD Display3½ Digit LCD
pH
Range0 to 14 pH0 to 14 pH
Resolution< 0.01 pH< 0.01 pH
Accuracy0.01± 1 digit0.01± 1 digit
Temp. Comp.0 to 100ºC (Auto/Manual)0 to 100ºC (Manual)
Conductivity (EC)
Range0-20, 0-200µs 0-2, 0-20, 0-200mS0-200µs 0-2, 0-20, 0-200mS
Resolution0.01µS/cm0.1µS
Range SelectionAutomaticManual
Accuracy±0.5% FS±1 digit±0.5% FS±1 digit
Cell ConstantAdjustable (0.05 to 10.5)Adjustable (0.4 to 1.5)
Temp. CoefficientAdjustable (0.4 to 4.0)2%
Temp. Comp.5-50º (Auto/Manual)Adjustable from table
Reference Temp.Selectable (5-50ºC)25ºC
Temperature
Range0-100ºC0-100ºC
Resolution0.1ºC0.1ºC
Accuracy±0.1ºC±1 digit±0.1ºC±1 digit
SensorSemi conductor typeSemi conductor type
TDS
Range0-20, 0-200ppm 0-2, 0-20, 0-200 ppt.0-200ppm 0-2, 0-20, 0-200 ppt.
Range SelectionAutomaticManual
Resolution0.01 ppm0.1 ppm
Accuracy±0.5% FS ± 1 Digit±0.5% FS ± 1 Digit
Cell constantAdjustable (0.05 to 10.5)0.4 to 1.25 on display
DO
Range0-20 ppm0-20 ppm
Resolution0.1 ppm0.1 ppm
Accuracy0.1 ppm ± 1 digit0.1 ppm ± 1 digit
Temp. Comp.Auto/Manual (5ºC to 55ºC)Manual (5ºC to 55ºC)
DO SensorGold/Silver ProbeGold/Silver Ambperometeric Probe
mV (ORP)
Range0 to ± 1999.9 mV0 to ± 1999 mV
Resolution0.1 mV1 mV
Accuracy±0.1mV ± 1 digit± 1 mV ± 1 digit
Turbidity
Range---------0-1000 JTU
Resolution---------1 JTU
Accuracy---------± 3% FS ± 1 Digit
Accuracy---------± 3% FS ± 1 Digit
Sample System---------30 mm clear Glass Tube
Salinity
Range0-20, 0-200 ppm, 0-2, 0-20, 0-50 ppt0-50 ppt
Resolution0.01 ppm0.1 ppt
Accuracy± 1% of Range ± 1 Digit± 0.5% FS ± 1 Digit
Power Supply6V Rechargeable Battery or 230 V ± 10% AC, 50 Hz1.5V x 6 Dry Cells or 230V ± 10% AC, 50Hz
Storage1000 Sample --------
Standard AccessoriespH Electrode, Cond./TDS/Salinity Cell, Temp. Probe, DO Probe, DO Probe, Dry Cell container (161), Main Lead, Operation Manual, Bottles for pH solutions & pH Tablets Bottles (161 & 191 ), Turbidity Test Tube Set (191)

Kheraexim one of the best ph meter manufacturers in India

Kheraxim is a well-known manufacturer and pH meter supplier. We provide an extensive type of pH Meter including the maximum superior microprocessor-based. There are also multiple functions such as pH Meters with auto temperature compensation and many more. As you know that, PH Meters are extremely useful for agricultural and soil evaluation laboratories, water first-class control in the boiler feedwater, swimming pools, fertilizer flowers, waterworks department, breweries, petroleum refineries, water purification flora etc. We- The best pH meter supplier provide a huge gamut of range in pH Meter to fit the pocket and necessities of various customers.

Features Of pH Meter

The portable pH Meter is scientifically designed for offering most balance and short results inside the field. These pH meters are the ideal preference for a high stop pH measurement. • They All Are PHS Series Microprocessor-Based Ph Meters • High Performance • Made On Advanced SMT Technology • Large LCD Display • Excellent Stability And Repeatability • Automatic Or Manual Temperature Compensation • Self-Diagnostic With Message Codes Display • Automatic Buffer Recognition

This microprocessor-based totally table pinnacle pH meter is capable of measuring pH/mV value and Ion awareness measurement with an Ion-selective electrode. These pH meters are right for habitual use in schools, laboratories and production plant life. Call us For more inquiry.